SBF1100 Dilution Extractive CEMS

Category:

Model:SBF1100

Overview:SBF1100 is a dillution extractive continuous emission monitoring system (CEMS), equipped with gas analyzers from HORIBA Japan and sampling probe from M&C Germany


Contact us         Inquiry

Product Features

Accurate wet measurement, continuous measurement of SO2 concentration, simultaneous display of NO/NO2/NOx concentration
Continuous measurement of CO/CO2 with alternating flow modulation infrared absorption technology, which can provide highly stable and high-precision measurement with extremely low drift over a long period of time
No need to heat the sampling line
High-precision dilution sampling probe and instant dilution technology reduce the water content of the sample gas and completely eliminate the influence of condensate
Calibration includes full system calibration and local calibration from the probe
Dilution technology solves the problem of blockage caused by high dust content in flue gas
Sample gas transmission is fast, maintenance workload is small, and consumables are few
Positive pressure transmission throughout the whole process, local minor leakage does not affect the measurement data


The system consists of:

Dilution sampling probe

Instrument gas processing unit

Flue gas analyzer

Probe control unit

Technical Parameters

SO2 Analyzer

Measurement Principle

Ultravoilet Fluorescence (UVF)

Measured Value

Concentration of SO2

Measuring Range

Standard: 0-0.05/0.1/0.2/0.5ppm

Optional: 4 ranges can be chosen within 0-10ppm (turndown ratio is within 10), measurement range can be chosen automatically or manually, remote switching

Detection Limited

0.5ppb (2σ) (measuring range≦0.2ppm)

0.5%F.S. (2σ) (measuring range>0.2ppm)


Reproducibility

±1.0%F.S.

Linearity

±1.0%F.S.

Zero Drift

±1.0%F.S./day (lowest range); ±2.0%F.S./week (lowest range)

Measurement Range Drift

±1.0%F.S./day (lowest range); ±2.0%F.S./week (lowest range)

Response Time (T90)

Within 120s (minimum range)

Sample Flow

Appr. 0.7L/min

Input/Output

0-1V/0-10V/4-20mA (need to specify)

Contact input/output

RS-232C

Ambient Temperature

5-40℃

Dimension

430(W)*550(D)*221(H)mm

Weight

Appr. 19kg


NOx Analyzer

Measurement Principle

Alternating Flow Modulated Decompression Chemiluminescence Detection (CLD)

Measured Values

Concentration of NO, NO2 and NOx

Measuring Range

Standard: 0-0.1/0.2/0.5/1.0ppm

Optional: 4 ranges can be chosen within 0-10ppm (turndown ratio is within 10), measurement range can be chosen automatically or manually, remote switching

Detection Limited

0.5ppb (2σ) (measuring range≦0.2ppm)

1.0%F.S.  (2σ) (measuring range>0.2ppm)

Reproducibility

±1.0%F.S.

Linearity

±1.0%F.S.

Zero Drift

±1.0%ppb/day or ±1.0%F.S./day(whichever is greater); ±2.0ppb/week or ±2.0%F.S./week (whichever is greater)

Measurement Range Drift

±1.0%F.S./day

±2.0%F.S./week

Response Time (T90)

Within 120s (minimum range)

Sample Flow

Appr. 0.8L/min

Input/Output

0-1V/0-10V/4-20mA (need to specify)

Contact input/output

RS-232C

Ambient Temperature

5-40℃

Dimension

430(W)*550(D)*221(H)mm

Weight

Appr. 21kg

Document Download

Recommended Products

QR CODE
MESSAGE TOP