Ion Chromatography System

Category:Chromatography

Model:IC-900 & IC-600

Overview:Ion Chromatography is widely used in environment, food, medical, chemistry, water quality, air quality detection, etc.


Contact us         Inquiry

Product Features

1. Intuitive observation with 5.0-inch high-brightness LCD, real-time display of parameters

2. Two-pole conductivity detector with temperature compensation and high sensitivity, suitable for laboratories with high sensitivity requirements

3. Fully compatible full PEEK flow paths are acid & alkali resistant and corrosion-free

4. Liquid level warning and self-processing system to automatically monitor low liquid level of the eluent and high liquid level of the waste, automatic pump stop and power off under abnormal conditions, safe and effective protection of the suppressor

5. More efficient patented constant current source device for current adjustment according to different conditions

6. Self-regenerating membrane suppressor with low background and high capacity, a perfect substitute for imported suppressors

7. “One button off” function

8. Built-in eluent preheating system to quickly and efficiently balance the eluent system

9. Imported manual six-port valve, leak proof up to 100,000 times of repeated switches

10. Self-innovated embedded column heater with imported grade A+ platinum resistance and   more accurate temperature measurement


Technical Parameters

Specification

IC-900

IC-600

Suppressor

Type

Anion and cation, electrodialytical membrane suppression

Dead Volume

<90 μL

Background

<1.0 μS/cm

Capacity

>100 μeq/min

Injection Valve

Type

6-port, built-in, manual

Withstand Pressure

35 MPa

Connection Pipe

1/16”

Flow Path Diameter

0.5 mm(0.02”)

Screw Specification

No.10-32UNF

Sample Loop

25 μL

Pump  

Pump Withstand Pressure

42 MPa (6000 psi)

35 MPa (5000 psi)

Max. Operating Pressure

5000 psi

4000psi

Flow Range

0.001-9.999 mL/min

Flow Accuracy

≤0.1%

Flow Repeatability

≤0.01%

Detector

Type

Electrical conductivity detector

Material

316 stainless steel, needle electrode

five-pole pulse ring passivated, 316 stainless steel

Cell Volume

≤0.8 μL

≤1.0 μL

Temperature Range

room temperature +5 °C-60 °C

---

Temperature Accuracy

±0.01 °C

---

Baseline Noise

≤0.2% FS

Baseline Drift:

≤1% FS

≤2% FS

Quantitative Repeatability

RSD≤1.0%

RSD≤2.0%

Qualitative Repeatability

RSD≤0.2%

Detection Limit

Cl-≤0.0006 μg/mL

Cl-≤0.001 μg/mL

Column Heater

Type

Imported grade A+ platinum resistance

---

Temperature Range

Ambient +5 °C-60 °C

---

Temperature Accuracy

±0.01 °C

---

Document Download

Recommended Products

QR CODE
MESSAGE TOP