Category:Spectroscopy
Model:530
Overview:Michelson Interferometer FTIR Spectrometer with a spectral range of 7800 to 350cm-1. It is a good choice for basic science research ananalysis, production quality control, testing and detection in various fields.
Real-time Diagnosis of Instrument Status
Real-time monitoring of instrument working status, performance and communication
"Internet + Detection" with Multiple Communication Options
Ethernet interface as standard supply for data transfer, WIFI wireless communication as an option, adapting to "Internet + detection" instrument development trend, setting up a basic platform for interconnected tests, remote operation and maintenance, and data cloud computing
High Sensitivity Optical System
Cube-corner Michelson interferometer combined with patented fixing mirror alignment technology (Utility model ZL 2013 2 0099730.2: fixing mirror alignment assembly), to ensure long term stability, without the need of dynamic alignment which needs extra complicated electronic circuits. Reflecting mirrors are coated with gold to provide the maximum light throughput and ensure the detection sensitivity.
High Stability Modular Partition Design
Compact structure modular design with layout on cast aluminum base and overall balance of mechanical robustness and partition heat dissipation, offering higher ability of deformation resistance and less sensitivie to vibrations and thermal variations, greatly improves the mechanical stability and long term working stability of the instrument
High Intensity IR Source Assembly
High intensity, long lifetime IR source module, with the highest energy distributed in fingerprint region, adopts a reflex sphere design to obtain even and stable IR radiation. External isolated IR source module and large space heat dissipation chamber design provide higher thermal stability and stable optical interference.
Intelligent Multi-Sealed Moisture-Proof Design
Multiple sealed interferometer, large-capacity desiccant cartridge with visible window and easy replacement structure, real-time monitoring of temperature and humidity inside the interferometer, getting rid of influences of high temperature, high humidity and chemical corrosions to the optical system in many ways.
Innovated Integration Electronic System
High sensitivity integrated DLATGS detector pre-amplifier technology, dynamic gain amplification technology, high precision 24-bit A/D conversion technology, real-time control and data processing technology, digital filter and network communication technology, ensuring high quality real-time data collection and high-speed transmission.
Good Anti-electromagnetic Interference Capability
The electronic system is designed to meet CE certification and electromagnetic compatibility requirements, minimizing electromagnetic radiation in design and technology, in line with green instrument designing concept
The Sampling Compartment
The sampling compartment reserving accessory mounting holes on the base plate, is wide enough for various accessories such as defused/specular reflection, ATR, liquid cell, gas cell, and IR microscope, etc.
Powerful MainFTOS Suite Software Workstation
Interferometer Cube-corner Michelson interferometer
Beam Splitter Multilayer Ge coated KBr
Detector Room temperature DLATGS module (standard)
Temperature stabilized, high sensitivity DLATGS module (optional)
IR Source High intensity, long lifetime, air-cooled IR source
Wavenumber Range 7800cm-1-350cm-1
Resolution 0.85cm-1
Signal to Noise Ratio Better than 20,000:1 (RMS value, at 2100cm-1-2000cm-1 or 2100cm-1-2200cm-1, resolution: 4cm-1, detector: DLATGS,
1 minute data collection)
Wavenumber Accuracy ±0.01cm-1
Scanning Speed Microprocessor control, different scanning speed selectable
Software MainFTOS Suite software workstation, compatible to all version Windows OS
Communication Ethenet interface (standard)
WIFI wireless communication (optional)
Data Output Standard data format, report generation and output
Status Diagnosis Power on self check, real-time temperature and humidity monitoring and reminders
Certification FDA 21 CFR Part 11 compliance, IQ/OQ/PQ (optional)
Environment Conditions Temperature: 10℃-30℃, humidity: less than 70%
Power Supply AC220±V22V, 50Hz±1Hz; AC110V (optional)
Dimensions & Weight 520*435*255, 24kg
Accessories Transmission sample holder (standard)
Gas cell, liquid cell, defused/specular reflection, single/multi reflection ATR, etc. (optional)